Danby DPAC10030 Bedienungshandbuch Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 65
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
6
External Water Tank Instructions (cont'd)
3.
Position the external water tank on the
support tray, making sure the quick connect
on the water tank is aligned with the quick
connect at the back of the cabinet.
See Fig.37
4. To make the connection, simply "push" the
water tank quick connect into the cabinet
quick connect. You will hear a positive
"click" when the connection is made.
5. Install both covers on the water tank.
6. To release (disconnect) the external water
tank, push the (silver) "release" button
located on the cabinet quick connect, grasp
the recessed handles on each side of the
tank and remove.
.
See fig.38, 39
Fig.38
Fig.37
Fig.39
CAUTION
Always empty both water tanks before attempting to
move or re-locate the unit to another location.
Fig. 40
Make sure the Internal
W
ater Tank
is correctly
positioned inside the cabinet otherwise the unit will
not operate.
Fig. 40.
Internal Water Tank Safety Feature
This unit is equipped with a fail-safe switch
mechanism which prevents the unit from condensing
water in the event the water tank is accidentally
displaced and/or when the water tank is full. If this
situation occurs, the unit will signal (
BEEP) for 20
seconds, the bucket icon in the display will flash
continuously and the (RED) WATER FULL indicator
light will illuminate. This condition will remain steady
until the water tank is re-positioned and/or emptied.
NOTE: The fan motor will continue to operate
under this condition. This is normal, but no
cooling or dehumidifying will occur until the
internal tank is emptied and/or re-positioned.
(NOTE: It may take several minutes before the
compressor resumes normal operation)
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 64 65

Kommentare zu diesen Handbüchern

Keine Kommentare