Electrical Specifications
1.
All wiring must comply with local and national
electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.
2. Check available power supply and resolve any
wiring problems BEFORE installation and
operation of this unit.
3. Model DPAC9030 draws 10.8 amps and Model
DPAC12030 draws 13.6 under
Cooling Mode
and may be used in any properly wired, general
purpose 15 amp household grounded receptacle.
4. For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a qualified
electrician. DO NOT USE PLUG ADAPTERS
OR EXTENSION CORDS WITH THIS UNIT.
If it is necessary to use an extension cord with
this unit, use an approved “air conditioner
extension cord only. (available at most local
hardware stores)
5. The manufacturers nameplate is located on the
rear panel of the unit and contains electrical and
other technical data specific to this unit.
6.
To avoid the possibility of personal injury, always
disconnect the power supply to the unit, before
installing and/or servicing.
Table 1
Suggested Individual Branch Circuit
Nameplate Amps AWG Wire Size*
10.8 to13.6 14
AWG- American Wire Gage
* Based on copper wire at 60°C temperature rating.
Table 2
Receptacle and Fuse Types
Rated V
olts 125
Amps 15
Wall Outlet
Fuse Size 15
Time Delay Fuse Plug Type
(or circuit breaker)
Unit Specifications: Model DPAC9030 DPAC12030
Cooling Capacity 9000 Btu/h 12000Btu/h
Dehumidifying Capacity 48 Pints (22.7 L / 24 Hrs) 71 Pints (33.6 L / 24 Hrs)
Noise Level 50 dB(A) 52 dB (A)
Power Source 1
15 V / 60 Hz 115 V / 60 Hz
Refrigerant R22 R22
Internal W
ater
T
ank Capacity 3.0 L
(6.3 Pints) 3.0 L
(6.3 Pints)
External Water Tank Capacity 15 L (31.7 Pints) 15 L (31.7 Pints)
Unit W
eight 40 kg (88.2 lb.) 40 kg (88.2 lb.)
Unit Dimensions (inches) W x D x H 17-3/8" x 18-1/4" x 33-9/16" 17-3/8" x 18-1/4" x 33-9/16"
Unit Dimensions (cm) W x D x H 44.1 x 46.3 x 85.3 44.1 x 46.3 x 85.3
Fan Speeds 3 3
Control Panel (Illuminated) Soft Touch Controls Soft Touch Controls
Remote Control Yes Yes
Time of Day Clock Yes Yes
Auto -
T
imer
Y
es
Yes
Power Consumption:
Cooling 1100 Watts (10.8 Amps) 1380 Watts (13.6 Amps)
Dehumidifying 1100 W (10.8 Amps) 1380 W (13.6 Amps)
Fan 90 W (0.8
Amps) 90 W (0.8
Amps)
NOTE: Specifications are subject to change without notice, for further improvements.