Danby Products Ltd. DCD5505W SCD5505W SERVICE MANUAL
MOISTURE SENSING IN THE ELECTRONIC DRYERS Previous system of moisture sensing plug rib tube spring Fig. 1: component parts of previous sens
In order to avoid this kind of failures, we have modified sensing mode as follows: Welded contact tape rib Fig. 3: component parts of new sen
SERVICE EQUIPMENT FOR SERVICING WASHING MACHINES AND DRIERS NAME DIM. Art. No.: PICTURE (SYMBOLIC) OPEN-END WRENCH 6 x 7 8 x 9 10 x 11 12 x 13
SERVICE EQUIPMENT FOR SERVICING WASHING MACHINES AND DRIERS NAME DIM. Art.No.: PICTURE (SYMBOLIC ) HAMMER 812/300 14393 RIVETER CL 7
SERVICE EQUIPMENT FOR SERVICING WASHING MACHINES AND DRIERS NAME DIM. Art.No.: PICTURE (SYMBOLIC ) MULTIMETER V,Ω, T(-40, +400), µA MAX, MIN FL
TROUBLE SHOOTING POSSIBLE FAULTS ON ELECTRONIC DRYERS, CAUSES AND REMEDY 1. DRYER NOT DRYING There is no contact brush-contact ring or no ear
INDEX 1. INTRODUCTION 2. EID SELECTOR 3. DISPLAY CARDS 4. PROGRAM SELECTION AND START 5. DRYING PROGRAM FLOW 6. HUMIDITY THRESHOLDS 7. MAINS S
REF # DESCRIPTION PART #26 BINDING CORNER PIECE 396858 •28 REAR WALL COVER 617150 •67 BELT 606532 •73 HINGE PLATE 537806 •86 CLAMP 547104 799 DOOR HIN
REF # DESCRIPTION PART #413 SIGNAL LIGHT 669912 •423 DRUM RIB 609850 2424 INNER POTENTIAL COLLECTOR 609856 2425 RIB SPRING 609852 2426 CONTACT PLUG 60
1. INTRODUCTION The DCD5505W electronic control is based on the SC4 platform concept. The DCD5505W product includes 3 modules: - a power board with
2. EID SELECTOR We use a 16 positions EID selector. The product has: - 1 stop position. - 5 cotton programs (positions 1 to 5) : control of the h
The End led is lighted from the beginning of the anti-crease phase and is extinguished when the mains supply is cut off. Tank led does not exist on a
If the user moves the EID on another drying program as one program is already running, the new one is not taken into account. For the Gorenje dryer ty
3s 20s 216s 3s 1s
6. HUMIDITY THRESHOLDS The relative humidity level of each laundry and drying type depends of a threshold value stored in the Eeprom of the SC4.